Q: How to calibrate load cell of Concrete Batching Plant?
A: 1. 5KG, 10KG, 20KG Standard weight prepared
2. Each scale hopper use the no less max. Weight 1/2 standard weight, if the standard weight quantity is not enough, it cannot less than 1/3 of max. Weight.
3. Check the scale hopper, no material, no blocking. Calibrate the “ZERO”
4. Put standard weight in the scale hopper, equally distributed.
5. Enter the standard weight into the computer, and calibrate the “end weight”.